{"title":"Overloads","description":"","products":[{"product_id":"siemens-sirius-3ru2126-4pb0-thermal-overload-relay-30-36-amp","title":"Siemens Sirius 3RU2126-4PB0 Thermal Overload Relay, 30-36 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2126-4PB0 Thermal Overload Relay, 30-36 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2126-4PB0 30-36 AMP OVERLOAD RELAY","offer_id":15902508318783,"sku":"CONT3RU21264PB0","price":89.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_e85147a2-1964-415e-92e1-3c33cdaffd00.JPG?v=1587152786"},{"product_id":"siemens-sirius-3ru2126-4fb0-thermal-overload-relay-34-40-amp","title":"Siemens Sirius 3RU2126-4FB0 Thermal Overload Relay, 34-40 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u003cspan id=\"mce_marker\" data-mce-type=\"bookmark\"\u003e﻿​\u003c\/span\u003e\u003cspan id=\"__caret\"\u003e_\u003c\/span\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2126-4FB0 Thermal Overload Relay, 34-40 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2126-4FB0 34-40 AMP OVERLOAD RELAY","offer_id":15902517198911,"sku":"CONT3RU21264FB0","price":83.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_7bbe9f7e-0134-421a-b542-5eceef87b061.JPG?v=1587152787"},{"product_id":"siemens-sirius-3ru2126-4eb0-thermal-overload-relay-27-32-amp","title":"Siemens Sirius 3RU2126-4EB0 Thermal Overload Relay, 27-32 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2126-4EB0 Thermal Overload Relay, 27-32 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2126-4EB0 27-32 AMP OVERLOAD RELAY","offer_id":15902525751359,"sku":"CONT3RU21264EB0","price":83.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_13183250-bfd9-49df-a375-2badf5377d45.JPG?v=1587152787"},{"product_id":"siemens-sirius-3ru2126-4db0-thermal-overload-relay-20-25-amp","title":"Siemens Sirius 3RU2126-4DB0 Thermal Overload Relay, 20-25 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2126-4DB0 Thermal Overload Relay, 20-25 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2126-4DB0 20-25 AMP OVERLOAD RELAY","offer_id":15902531846207,"sku":"CONT3RU21264DB0","price":55.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_fad54670-0f91-44c6-83f3-6cc9ebfb9707.JPG?v=1587152788"},{"product_id":"siemens-sirius-3ru2126-4bb0-thermal-overload-relay-14-20-amp","title":"Siemens Sirius 3RU2126-4BB0 Thermal Overload Relay, 14-20 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2126-4BB0 Thermal Overload Relay, 14-20 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2126-4BB0 14-20 AMP OVERLOAD RELAY","offer_id":15902535843903,"sku":"CONT3RU21264BB0","price":52.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_7475b4a7-5781-4fb1-a9f5-a3ba71f2bd78.JPG?v=1587152789"},{"product_id":"siemens-sirius-3ru2126-4ab0-thermal-overload-relay-11-16-amp","title":"Siemens Sirius 3RU2126-4AB0 Thermal Overload Relay, 11-16 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u003cspan id=\"mce_marker\" data-mce-type=\"bookmark\"\u003e﻿​\u003c\/span\u003e\u003cspan id=\"__caret\"\u003e_\u003c\/span\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2126-4AB0 Thermal Overload Relay, 11-16 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2126-4AB0 11-16 AMP OVERLOAD RELAY","offer_id":15902542954559,"sku":"CONT3RU21264AB0","price":53.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_bd646708-6f20-4b92-9251-1e4e83077d75.JPG?v=1587152789"},{"product_id":"siemens-sirius-3ru2126-1jb0-thermal-overload-relay-7-0-10-amp","title":"Siemens Sirius 3RU2126-1JB0 Thermal Overload Relay, 7.0-10 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u003cspan id=\"mce_marker\" data-mce-type=\"bookmark\"\u003e﻿​\u003c\/span\u003e\u003cspan id=\"__caret\"\u003e_\u003c\/span\u003e\u003c!--\n\u003cspan id=\"mce_marker\" data-mce-type=\"bookmark\"\u003e﻿​\u003c\/span\u003e\u003cspan id=\"__caret\"\u003e_\u003c\/span\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2126-1JB0 Thermal Overload Relay, 7.0-10 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003c\/p\u003e\n\u003cp\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2126-1JB0 7.0-10 AMP OVERLOAD RELAY","offer_id":15902554521663,"sku":"CONT3RU21261JB0","price":51.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_b4a982f6-19d2-4a0b-b832-35f00523c0dc.JPG?v=1587152790"},{"product_id":"siemens-sirius-3ru2126-1hb0-thermal-overload-relay-5-5-8-0-amp","title":"Siemens Sirius 3RU2126-1HB0 Thermal Overload Relay, 5.5-8.0 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2126-1HB0 Thermal Overload Relay, 5.5-8.0 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2126-1HB0 5.5-8.0 AMP OVERLOAD RELAY","offer_id":15902558650431,"sku":"CONT3RU21261HB0","price":55.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_d332077e-8fb6-41c2-b0ce-b672f10a1394.JPG?v=1587152791"},{"product_id":"siemens-sirius-3ru2126-1gb0-thermal-overload-relay-4-5-6-3-amp","title":"Siemens Sirius 3RU2126-1GB0 Thermal Overload Relay, 4.5-6.3 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2126-1GB0 Thermal Overload Relay, 4.5-6.3 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2126-1GB0 4.5-6.3 AMP OVERLOAD RELAY","offer_id":15902563270719,"sku":"CONT3RU21261GB0","price":54.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_8971e1ea-03a6-421a-a160-3e68166c04a6.JPG?v=1587152791"},{"product_id":"siemens-sirius-3ru2116-1kb0-thermal-overload-relay-9-0-12-5-amp","title":"Siemens Sirius 3RU2116-1KB0 Thermal Overload Relay, 9.0-12.5 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1KB0 Thermal Overload Relay, 9.0-12.5 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2116-1KB0 9.0-12.5 AMP OVERLOAD RELAY","offer_id":15902581030975,"sku":"CONT3RU21161KB0","price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_8c9a8303-6478-4394-8f4f-186a8561a475.JPG?v=1587152792"},{"product_id":"siemens-sirius-3ru2116-1fb0-thermal-overload-relay-3-5-5-0-amp","title":"Siemens Sirius 3RU2116-1FB0 Thermal Overload Relay, 3.5-5.0 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1FB0 Thermal Overload Relay, 3.5-5.0 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2116-1FB0 3.5-5.0 AMP OVERLOAD RELAY","offer_id":15902595907647,"sku":"CONT3RU21161FB0","price":51.65,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_251c2e7e-f439-45fa-ad0c-6379c78948b4.JPG?v=1587152793"},{"product_id":"siemens-sirius-3ru2116-1db0-thermal-overload-relay-2-2-3-2-amp","title":"Siemens Sirius 3RU2116-1DB0 Thermal Overload Relay, 2.2-3.2 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1DB0 Thermal Overload Relay, 2.2-3.2 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2116-1DB0 2.2-3.2 AMP OVERLOAD RELAY","offer_id":15902611341375,"sku":"CONT3RU21161DB0","price":51.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_d7bd4115-8aa0-40ab-93a3-c0a972c82bc1.JPG?v=1587152793"},{"product_id":"siemens-sirius-3ru2116-1cb0-thermal-overload-relay-1-8-2-5-amp","title":"Siemens Sirius 3RU2116-1CB0 Thermal Overload Relay, 1.8-2.5 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1CB0 Thermal Overload Relay, 1.8-2.5 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2116-1CB0 1.8-2.5 AMP OVERLOAD RELAY","offer_id":15902618255423,"sku":"CONT3RU21161CB0","price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_cb7d6a44-4644-45e4-abbf-04c5cd8e07cb.JPG?v=1587152794"},{"product_id":"siemens-sirius-3ru2116-1bb0-thermal-overload-relay-1-4-2-0-amp","title":"Siemens Sirius 3RU2116-1BB0 Thermal Overload Relay, 1.4-2.0 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1BB0 Thermal Overload Relay, 1.4-2.0 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2116-1BB0 1.4-2.0 AMP OVERLOAD RELAY","offer_id":15902625660991,"sku":"CONT3RU21161BB0","price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_3c76acf2-d888-41af-9c9d-1bde8b5bc160.JPG?v=1587152795"},{"product_id":"siemens-sirius-3ru2116-1ab0-thermal-overload-relay-1-1-1-6-amp","title":"Siemens Sirius 3RU2116-1AB0 Thermal Overload Relay, 1.1-1.6 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1AB0 Thermal Overload Relay, 1.1-1.6 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2116-1AB0 1.1-1.6 AMP OVERLOAD RELAY","offer_id":15902639489087,"sku":"CONT3RU21161AB0","price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_6a7213e4-1f6f-4e32-ab19-be1f6d37f95a.JPG?v=1587152795"},{"product_id":"siemens-sirius-3ru2116-0jb0-thermal-overload-relay-0-7-1-0-amp","title":"Siemens Sirius 3RU2116-0JB0 Thermal Overload Relay, 0.7-1.0 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-0JB0 Thermal Overload Relay, 0.7-1.0 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"3RU2116-0JB0 0.7- 1.0 AMP OVERLOAD RELAY","offer_id":15902655381567,"sku":"CONT3RU21160JB0","price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_c3c574cc-a445-4cb3-b1f4-7ddbfb11c3b9.JPG?v=1587152796"},{"product_id":"siemens-sirius-3ru2116-1eb0-thermal-overload-relay-2-8-4-0-amp","title":"Siemens Sirius 3RU2116-1EB0 Thermal Overload Relay, 2.8-4.0 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1EB0 Thermal Overload Relay, 2.8-4.0 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":41602525921465,"sku":"CONT3RU21161EB0","price":51.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_34378c2e-5db8-4d69-94c8-f863931fefad.jpg?v=1638454357"},{"product_id":"siemens-sirius-3ru2116-1gb0-thermal-overload-relay-4-5-6-3-amp","title":"Siemens Sirius 3RU2116-1GB0 Thermal Overload Relay, 4.5-6.3 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1GB0 Thermal Overload Relay, 4.5-6.3 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":41602534539449,"sku":"CONT3RU21161GB0","price":51.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_23065f02-c8d5-40d3-959c-f086d8851408.jpg?v=1638454675"},{"product_id":"siemens-sirius-3ru2116-1hb0-thermal-overload-relay-5-5-8-0-amp","title":"Siemens Sirius 3RU2116-1HB0 Thermal Overload Relay, 5.5-8.0 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1HB0 Thermal Overload Relay, 5.5-8.0 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":41602536374457,"sku":"CONT3RU21161HB0","price":51.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_1f886096-2de0-4a91-9363-8017d47c0c66.jpg?v=1638454791"},{"product_id":"siemens-sirius-3ru2116-1jb0-thermal-overload-relay-7-0-10-0-amp","title":"Siemens Sirius 3RU2116-1JB0 Thermal Overload Relay, 7.0-10.0 Amp","description":"\u003cstyle type=\"text\/css\"\u003e\u003c!--\n\u0026lt;!--td {border: 1px solid #ccc;}br {mso-data-placement:same-cell;}--\u0026gt;\n--\u003e\u003c\/style\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eSiemens Sirius 3RU2116-1JB0 Thermal Overload Relay, 7.0-10.0 Amp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSIRIUS 3RU thermal overload relays\u003cbr\u003eIn the main circuit, the SIRIUS 3RU thermal overload relays are responsible for current-dependent overload protection of electrical loads (e.g. motors).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":41602537128121,"sku":"CONT3RU21161JB0","price":51.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/IMG_8752_a4f80b0a-6957-4bcd-b8fd-86a4dd3412a2.jpg?v=1638454872"},{"product_id":"schneider-lr2k0305-thermal-overload-relay-tesys-k-0-54-to-0-8-amp","title":"Schneider LR2K0305 Thermal Overload Relay, TeSys K, 0.54 to 0.8 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR2K0305 Thermal Overload Relay, TeSys K, 0.54 to 0.8 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR2K0305  is a TeSys LRK thermal overload relay from Schneider Electric designed to be used with TeSys K contactors to make a motor starter. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 0.54 to 0.8 amperes. This trip current rating is calibrated per Class 10A. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR2K0305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLP4K \u003cbr\u003eLC1K \u003cbr\u003eLP1K \u003cbr\u003eLC7K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eDC \u003cbr\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e0.54…0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 690 V BS 4941 \u003cbr\u003ePower circuit 690 V IEC 60947 \u003cbr\u003ePower circuit 750 V VDE 0110 group C \u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 690 V power circuit \u003cbr\u003e690 V AC AC-15 signaling circuit \u003cbr\u003e250 V DC DC-13 signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A gG for signaling circuit conforming to VDE 0660 \u003cbr\u003e6 A gG for signaling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eYes IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTrip indicator Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button trip test function \u003cbr\u003eBlue push-button stop and manual reset \u003cbr\u003eselector switch manual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003escrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end \u003cbr\u003escrew clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNF C 63-650\u003c\/li\u003e\n\u003cli\u003eIEC 60947\u003c\/li\u003e\n\u003cli\u003eVDE 0660\u003c\/li\u003e\n\u003cli\u003eBS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48151835508921,"sku":"CONTSCHLR2K0305","price":67.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR2K0305.jpg?v=1784145253"},{"product_id":"schneider-lr2k0306-thermal-overload-relay-tesys-k-0-8-to-1-2-amp","title":"Schneider LR2K0306 Thermal Overload Relay, TeSys K, 0.8 to 1.2 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR2K0306 Thermal Overload Relay, TeSys K, 0.8 to 1.2 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR2K0306 is a TeSys LRK thermal overload relay from Schneider Electric designed to be used with TeSys K contactors to make a motor starter. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 0.8 to 1.2 amperes. This trip current rating is calibrated per Class 10A. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR2K0306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1K \u003cbr\u003eLC7K \u003cbr\u003eLP4K \u003cbr\u003eLP1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e0.8…1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 690 V BS 4941 \u003cbr\u003ePower circuit 690 V IEC 60947 \u003cbr\u003ePower circuit 750 V VDE 0110 group C \u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 690 V power circuit \u003cbr\u003e690 V AC AC-15 signaling circuit \u003cbr\u003e250 V DC DC-13 signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A gG for signaling circuit conforming to VDE 0660 \u003cbr\u003e6 A gG for signaling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eYes IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTrip indicator Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button trip test function \u003cbr\u003eBlue push-button stop and manual reset \u003cbr\u003eselector switch manual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003escrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end \u003cbr\u003escrew clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNF C 63-650\u003c\/li\u003e\n\u003cli\u003eIEC 60947\u003c\/li\u003e\n\u003cli\u003eVDE 0660\u003c\/li\u003e\n\u003cli\u003eBS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48152145756345,"sku":"CONTSCHLR2K0306","price":67.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR2K0306.jpg?v=1784216342"},{"product_id":"schneider-lr2k0307-thermal-overload-relay-tesys-k-1-2-to-1-8-amp","title":"Schneider LR2K0307 Thermal Overload Relay, TeSys K, 1.2 to 1.8 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR2K0307 Thermal Overload Relay, TeSys K, 1.2 to 1.8 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR2K0307 is a TeSys LRK thermal overload relay from Schneider Electric designed to be used with TeSys K contactors to make a motor starter. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 1.2 to 1.8 amperes. This trip current rating is calibrated per Class 10A. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR2K0307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1K \u003cbr\u003eLC7K \u003cbr\u003eLP4K \u003cbr\u003eLP1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1.2…1.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 690 V BS 4941 \u003cbr\u003ePower circuit 690 V IEC 60947 \u003cbr\u003ePower circuit 750 V VDE 0110 group C \u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 690 V power circuit \u003cbr\u003e690 V AC AC-15 signaling circuit \u003cbr\u003e250 V DC DC-13 signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A gG for signaling circuit conforming to VDE 0660 \u003cbr\u003e6 A gG for signaling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eYes IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTrip indicator Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button trip test function \u003cbr\u003eBlue push-button stop and manual reset \u003cbr\u003eselector switch manual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003escrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end \u003cbr\u003escrew clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNF C 63-650\u003c\/li\u003e\n\u003cli\u003eIEC 60947\u003c\/li\u003e\n\u003cli\u003eVDE 0660\u003c\/li\u003e\n\u003cli\u003eBS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48152465998009,"sku":"CONTSCHLR2K0307","price":67.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR2K0307.jpg?v=1784218453"},{"product_id":"schneider-lr2k0308-thermal-overload-relay-tesys-k-1-8-to-2-6-amp","title":"Schneider LR2K0308 Thermal Overload Relay, TeSys K, 1.8 to 2.6 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR2K0308 Thermal Overload Relay, TeSys K, 1.8 to 2.6 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR2K0308 is a TeSys LRK thermal overload relay from Schneider Electric designed to be used with TeSys K contactors to make a motor starter. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 1.8 to 2.6 amperes. This trip current rating is calibrated per Class 10A. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR2K0308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1K \u003cbr\u003eLC7K \u003cbr\u003eLP4K \u003cbr\u003eLP1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1.8…2.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 690 V BS 4941 \u003cbr\u003ePower circuit 690 V IEC 60947 \u003cbr\u003ePower circuit 750 V VDE 0110 group C \u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 690 V power circuit \u003cbr\u003e690 V AC AC-15 signaling circuit \u003cbr\u003e250 V DC DC-13 signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A gG for signaling circuit conforming to VDE 0660 \u003cbr\u003e6 A gG for signaling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eYes IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTrip indicator Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button trip test function \u003cbr\u003eBlue push-button stop and manual reset \u003cbr\u003eselector switch manual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003escrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end \u003cbr\u003escrew clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNF C 63-650\u003c\/li\u003e\n\u003cli\u003eIEC 60947\u003c\/li\u003e\n\u003cli\u003eVDE 0660\u003c\/li\u003e\n\u003cli\u003eBS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48153153994937,"sku":"CONTSCHLR2K0308","price":67.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR2K0308.jpg?v=1784225711"},{"product_id":"schneider-lr2k0310-thermal-overload-relay-tesys-k-2-6-to-3-7-amp","title":"Schneider LR2K0310 Thermal Overload Relay, TeSys K, 2.6 to 3.7 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR2K0310 Thermal Overload Relay, TeSys K, 2.6 to 3.7 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR2K0310 is a TeSys LRK thermal overload relay from Schneider Electric designed to be used with TeSys K contactors to make a motor starter. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 2.6 to 3.7 amperes. This trip current rating is calibrated per Class 10A. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR2K0310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1K \u003cbr\u003eLC7K \u003cbr\u003eLP4K \u003cbr\u003eLP1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2.6…3.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 690 V BS 4941 \u003cbr\u003ePower circuit 690 V IEC 60947 \u003cbr\u003ePower circuit 750 V VDE 0110 group C \u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 690 V power circuit \u003cbr\u003e690 V AC AC-15 signaling circuit \u003cbr\u003e250 V DC DC-13 signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A gG for signaling circuit conforming to VDE 0660 \u003cbr\u003e6 A gG for signaling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eYes IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTrip indicator Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button trip test function \u003cbr\u003eBlue push-button stop and manual reset \u003cbr\u003eselector switch manual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003escrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end \u003cbr\u003escrew clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNF C 63-650\u003c\/li\u003e\n\u003cli\u003eIEC 60947\u003c\/li\u003e\n\u003cli\u003eVDE 0660\u003c\/li\u003e\n\u003cli\u003eBS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48153195413689,"sku":"CONTSCHLR2K0310","price":67.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR2K0310.jpg?v=1784227361"},{"product_id":"schneider-lr2k0312-thermal-overload-relay-tesys-k-3-7-to-5-5-amp","title":"Schneider LR2K0312 Thermal Overload Relay, TeSys K, 3.7 to 5.5 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR2K0312 Thermal Overload Relay, TeSys K, 3.7 to 5.5 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR2K0312 is a TeSys LRK thermal overload relay from Schneider Electric designed to be used with TeSys K contactors to make a motor starter. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 3.7 to 5.5 amperes. This trip current rating is calibrated per Class 10A. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR2K0312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1K \u003cbr\u003eLC7K \u003cbr\u003eLP4K \u003cbr\u003eLP1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e3.7…5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 690 V BS 4941 \u003cbr\u003ePower circuit 690 V IEC 60947 \u003cbr\u003ePower circuit 750 V VDE 0110 group C \u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 690 V power circuit \u003cbr\u003e690 V AC AC-15 signaling circuit \u003cbr\u003e250 V DC DC-13 signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A gG for signaling circuit conforming to VDE 0660 \u003cbr\u003e6 A gG for signaling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eYes IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTrip indicator Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button trip test function \u003cbr\u003eBlue push-button stop and manual reset \u003cbr\u003eselector switch manual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003escrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end \u003cbr\u003escrew clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNF C 63-650\u003c\/li\u003e\n\u003cli\u003eIEC 60947\u003c\/li\u003e\n\u003cli\u003eVDE 0660\u003c\/li\u003e\n\u003cli\u003eBS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48163284320441,"sku":"CONTSCHLR2K0312","price":67.76,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR2K0312.jpg?v=1784293790"},{"product_id":"schneider-lr2k0314-thermal-overload-relay-tesys-k-5-5-to-8-amp","title":"Schneider LR2K0314 Thermal Overload Relay, TeSys K, 5.5 to 8 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR2K0314 Thermal Overload Relay, TeSys K, 5.5 to 8 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR2K0314 is a TeSys LRK thermal overload relay from Schneider Electric designed to be used with TeSys K contactors to make a motor starter. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 5.5 to 8 amperes. This trip current rating is calibrated per Class 10A. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR2K0314\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1K \u003cbr\u003eLC7K \u003cbr\u003eLP4K \u003cbr\u003eLP1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e5.5...8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 690 V BS 4941 \u003cbr\u003ePower circuit 690 V IEC 60947 \u003cbr\u003ePower circuit 750 V VDE 0110 group C \u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 690 V power circuit \u003cbr\u003e690 V AC AC-15 signaling circuit \u003cbr\u003e250 V DC DC-13 signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A gG for signaling circuit conforming to VDE 0660 \u003cbr\u003e6 A gG for signaling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eYes IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTrip indicator Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button trip test function \u003cbr\u003eBlue push-button stop and manual reset \u003cbr\u003eselector switch manual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003escrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end \u003cbr\u003escrew clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNF C 63-650\u003c\/li\u003e\n\u003cli\u003eIEC 60947\u003c\/li\u003e\n\u003cli\u003eVDE 0660\u003c\/li\u003e\n\u003cli\u003eBS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48163705716921,"sku":"CONTSCHLR2K0314","price":67.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR2K0314.jpg?v=1784296805"},{"product_id":"schneider-lr2k0316-thermal-overload-relay-tesys-k-8-to-11-5-amp","title":"Schneider LR2K0316 Thermal Overload Relay, TeSys K, 8 to 11.5 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR2K0316 Thermal Overload Relay, TeSys K, 8 to 11.5 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR2K0316 is a TeSys LRK thermal overload relay from Schneider Electric designed to be used with TeSys K contactors to make a motor starter. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 8 to 11.5 amperes. This trip current rating is calibrated per Class 10A. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR2K0316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1K \u003cbr\u003eLC7K \u003cbr\u003eLP4K \u003cbr\u003eLP1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e8...11.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 690 V BS 4941 \u003cbr\u003ePower circuit 690 V IEC 60947 \u003cbr\u003ePower circuit 750 V VDE 0110 group C \u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 690 V power circuit \u003cbr\u003e690 V AC AC-15 signaling circuit \u003cbr\u003e250 V DC DC-13 signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A gG for signaling circuit conforming to VDE 0660 \u003cbr\u003e6 A gG for signaling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eYes IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTrip indicator Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button trip test function \u003cbr\u003eBlue push-button stop and manual reset \u003cbr\u003eselector switch manual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003escrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end \u003cbr\u003escrew clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNF C 63-650\u003c\/li\u003e\n\u003cli\u003eIEC 60947\u003c\/li\u003e\n\u003cli\u003eVDE 0660\u003c\/li\u003e\n\u003cli\u003eBS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48163990732985,"sku":"CONTSCHLR2K0316","price":67.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR2K0316.jpg?v=1784298072"},{"product_id":"schneider-lr2k0321-thermal-overload-relay-tesys-k-10-to-14-amp","title":"Schneider LR2K0321 Thermal Overload Relay, TeSys K, 10 to 14 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR2K0321 Thermal Overload Relay, TeSys K, 10 to 14 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR2K0321 is a TeSys LRK thermal overload relay from Schneider Electric designed to be used with TeSys K contactors to make a motor starter. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 10 to 14 amperes. This trip current rating is calibrated per Class 10A. It provides manual test \u0026amp; reset buttons, automatic reset, trip auxiliary contact and flag indicator. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR2K0321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1K \u003cbr\u003eLC7K \u003cbr\u003eLP4K \u003cbr\u003eLP1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e10...14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 690 V BS 4941 \u003cbr\u003ePower circuit 690 V IEC 60947 \u003cbr\u003ePower circuit 750 V VDE 0110 group C \u003cbr\u003ePower circuit 600 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 690 V power circuit \u003cbr\u003e690 V AC AC-15 signaling circuit \u003cbr\u003e250 V DC DC-13 signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 A gG for signaling circuit conforming to VDE 0660 \u003cbr\u003e6 A gG for signaling circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eYes IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTrip indicator Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button trip test function \u003cbr\u003eBlue push-button stop and manual reset \u003cbr\u003eselector switch manual or automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003escrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid \u003cbr\u003escrew clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end \u003cbr\u003escrew clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end \u003cbr\u003escrew clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm \u003cbr\u003e11.5 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNF C 63-650\u003c\/li\u003e\n\u003cli\u003eIEC 60947\u003c\/li\u003e\n\u003cli\u003eVDE 0660\u003c\/li\u003e\n\u003cli\u003eBS 4941\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48164309172409,"sku":"CONTSCHLR2K0321","price":67.76,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR2K0321.jpg?v=1784299607"},{"product_id":"schneider-lr3d21-thermal-overload-relay-tesys-deca-12-to-18-amp","title":"Schneider LR3D21 Thermal Overload Relay, TeSys Deca, 12 to 18 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR3D21 Thermal Overload Relay, TeSys Deca, 12 to 18 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR3D21 is a TeSys LRD thermal overload protection relay, bimetallic type, from Schneider Electric designed for direct mounting on TeSys D contactors to make a compact motor starter. With a thermal setting range 12-18A and a tripping class 10A, it protects unbalanced loads and motors 7.5kW@400V. It provides manual test and reset buttons, automatic reset, trip auxiliary contact and flag indicator. Direct mounting on the bottom terminals of a TeSys contactor LC1D18-D38 (to be ordered separately) to form a compact starter. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR3D21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys \u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1D18\u003cbr\u003eLC1D32 \u003cbr\u003eLC1D25 \u003cbr\u003eLC1D38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e12...18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 600 V CSA \u003cbr\u003ePower circuit 600 V UL \u003cbr\u003ePower circuit 690 V IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTripping Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1.14 +\/- 0.06 Ir IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e5 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePermissible Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1.5 A 240 V AC-15 signalling circuit \u003cbr\u003e0.1 A 250 V DC-13 signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e690 V AC 0...400 Hz power circuit IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e4 A gG for signalling circuit \u003cbr\u003e4 A BS for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTripping current 130 % of Ir on two phase, the last one at 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button stop \u003cbr\u003eBlue push-button reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e-4…140 °F (-20…60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end \u003cbr\u003eControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end \u003cbr\u003eControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without cable end \u003cbr\u003ePower circuit screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) flexible without cable end \u003cbr\u003ePower circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) flexible with cable end \u003cbr\u003ePower circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals \u003cbr\u003ePower circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003cli\u003eEN 50495\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eRINA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eLROS (Lloyds register of shipping)\u003c\/li\u003e\n\u003cli\u003eATEX INERIS\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48167661994169,"sku":"CONTSCHLR3D21","price":99.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR3D21.jpg?v=1784314755"},{"product_id":"schneider-lr3d22-thermal-overload-relay-tesys-deca-16-to-24-amp","title":"Schneider LR3D22 Thermal Overload Relay, TeSys Deca, 16 to 24 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR3D22 Thermal Overload Relay, TeSys Deca, 16 to 24 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR3D22 is a TeSys LRD thermal overload protection relay, bimetallic type, from Schneider Electric designed for direct mounting on TeSys D contactors to make a compact motor starter. With a thermal setting range 16-24A and a tripping class 10A, it protects unbalanced loads and motors 11kW@400V. It provides manual test and reset buttons, automatic reset, trip auxiliary contact and flag indicator. Direct mounting on the bottom terminals of a TeSys contactor LC1D25-D38 (to be ordered separately) to form a compact starter. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR3D22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys \u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1D32 \u003cbr\u003eLC1D25 \u003cbr\u003eLC1D38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e16...24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 600 V CSA \u003cbr\u003ePower circuit 600 V UL \u003cbr\u003ePower circuit 690 V IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTripping Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1.14 +\/- 0.06 Ir IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e5 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePermissible Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1.5 A 240 V AC-15 signalling circuit \u003cbr\u003e0.1 A 250 V DC-13 signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e690 V AC 0...400 Hz power circuit IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e4 A gG for signalling circuit \u003cbr\u003e4 A BS for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTripping current 130 % of Ir on two phase, the last one at 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button stop \u003cbr\u003eBlue push-button reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e-4…140 °F (-20…60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end \u003cbr\u003eControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end \u003cbr\u003eControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without cable end \u003cbr\u003ePower circuit screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) flexible without cable end \u003cbr\u003ePower circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) flexible with cable end \u003cbr\u003ePower circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals \u003cbr\u003ePower circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003cli\u003eEN 50495\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eRINA\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eLROS (Lloyds register of shipping)\u003c\/li\u003e\n\u003cli\u003eATEX INERIS\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48256999882937,"sku":"CONTSCHLR3D22","price":99.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LRD22.jpg?v=1784555063"},{"product_id":"schneider-lr3d332-thermal-overload-relay-tesys-deca-23-to-32-amp","title":"Schneider LR3D332 Thermal Overload Relay, TeSys Deca, 23 to 32 Amp","description":"\u003ch2\u003e\u003cstrong\u003eSchneider LR3D332 Thermal Overload Relay, TeSys Deca, 23 to 32 Amp\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eLR3D332 is a TeSys LRD thermal overload protection relay, bimetallic type, from Schneider Electric designed for direct mounting on TeSys D contactors to make a compact motor starter. With a thermal setting range 23-32A and a tripping class 10A, it protects unbalanced loads and motors 15kW@400V. It provides manual test and reset buttons, automatic reset, trip auxiliary contact and flag indicator. Direct mounting on the bottom terminals of a TeSys contactor LC1D40A-D65A (to be ordered separately) to form a compact starter. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03). Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC).\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLR3D332\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTeSys \u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eRelay Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eMotor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eLC1D40A \u003cbr\u003eLC1D50A \u003cbr\u003eLC1D65A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eAC \u003cbr\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Overload Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eClass 10A IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eThermal Protection Adjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e23...32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003ePower circuit 600 V CSA \u003cbr\u003ePower circuit 600 V UL \u003cbr\u003ePower circuit 690 V IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e\u0026lt;= 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eUnder contactor \u003cbr\u003ePlate, with specific accessories \u003cbr\u003eRail, with specific accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTripping Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1.14 +\/- 0.06 Ir IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAuxiliary Contact Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e5 A signaling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePermissible Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e0.95 A 380 V AC-15 signalling circuit \u003cbr\u003e0.06 A 440 V DC-13 signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e690 V AC 0...400 Hz power circuit IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e4 A gG for signalling circuit \u003cbr\u003e4 A BS for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eTripping current 130 % of Ir on two phase, the last one at 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eRed push-button stop \u003cbr\u003eBlue push-button reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003e-4…140 °F (-20…60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eConnections - Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end \u003cbr\u003eControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end \u003cbr\u003eControl circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without cable end \u003cbr\u003ePower circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) flexible without cable end \u003cbr\u003ePower circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) flexible with cable end \u003cbr\u003ePower circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) solid without cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 45%;\"\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 55%; text-align: center;\"\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals \u003cbr\u003ePower circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-4-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-4-1\u003c\/li\u003e\n\u003cli\u003eUL 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-4-1\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 60947-5-1\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.4\u003c\/li\u003e\n\u003cli\u003eGB\/T 14048.5\u003c\/li\u003e\n\u003cli\u003eEN 50495\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEC\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eDNV-GL\u003c\/li\u003e\n\u003cli\u003eRMRS\u003c\/li\u003e\n\u003cli\u003eEU-RO MR\u003c\/li\u003e\n\u003cli\u003eLROS (Lloyds register of shipping)\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48257271038137,"sku":"CONTSCHLR3D332","price":171.61,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/Schneider_Electric_LR3D332.jpg?v=1784562327"}],"url":"https:\/\/shop.prmfiltration.com\/collections\/overloads.oembed?page=2","provider":"PRM Filtration","version":"1.0","type":"link"}