{"title":"ATI","description":"\u003cp\u003ePRM offers sensors and monitors for oxygen and ozone.\u003c\/p\u003e","products":[{"product_id":"ati-f12-d-toxic-gas-detector","title":"ATI F12\/IS Oxygen\/Ozone Gas Detector","description":"\u003cp\u003e\u003cstrong\u003eATI F12-IS Toxic Gas Detector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/ATI_s_F12-iS_Intrisically_Safe_Gas_Transmitter.pdf?v=1630000648\"\u003eATI-F12\/IS Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/ATI_F12_Toxic_Gas_Transmitter_Typical_Specs.pdf?v=1630000616\"\u003eATI F12 Typical Specification\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eATI's F12iS Toxic Gas Detector is designed to measure toxic gases and oxygen in hazardous locations requiring an Intrinsically Safe (IS) device. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eFor many toxic gases, ATI offers a unique sensor response testing system unmatched by any competitive gas transmitter. Even outdoors in high wind conditions, the Auto-Test system provides reliable response checks to ensure system integrity. Sensor response is verified with an actual gas sample that is generated on demand. Generators store run time information accessible to operators, and are automatically tested for compatibility with the installed electrochemical sensors.\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eF12 gas detectors provide useful features that simplify installation, operation, and maintenance. The 4-button keypad is used to configure the menu-driven setup pages. The display also provides alarm indication and complete menus for setting up operating parameters.\u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eEach version utilizes a digital communications protocol. The IS version of the gas transmitter is available with HART™ communications. The HART™ protocol supports the HART™ Universal and Common Practice Commands at 1200 baud using the Bell 202 FSK modem standard. The non-IS version of the transmitter is available with MODBUS™ communications. The MODBUS™ protocol supports 9600 baud access to concentration and status information, and supports alarm setup and many other functions on either RS485 or RS232 (software selectable).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: Loop-powered 24 VDC\u003c\/li\u003e\n\u003cli\u003eInterchangeable Sensors: The F12iS accommodates 60 different\u003cbr data-mce-fragment=\"1\"\u003esensor modules, sensor modules sold separately\u003c\/li\u003e\n\u003cli\u003eInternal Data Logger: Gas values are stored at user defined intervals from\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 to 60 minutes. Stored data may be reviewed or graphed on the LCD display\u003c\/li\u003e\n\u003cli\u003eCalibration History: Sensor calibration adjustments of zero and span are stored in sensor memory and may be viewed on the F12iS display\u003c\/li\u003e\n\u003cli\u003e Communication: F12iS is available with optional Hart® output\u003c\/li\u003e\n\u003cli\u003eApprovals: CE and RoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ATI","offers":[{"title":"Default Title","offer_id":40842403414201,"sku":"OZONEF12IS1111","price":1299.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/ATI.jpg?v=1629993195"},{"product_id":"model-h10-14-low-range-ozone-o3-smart-sensor","title":"ATI Model H10-14 Low Range Ozone (O3) Smart Sensor (Use with F12 Toxic Gas Transmitter)","description":"\u003cp\u003e\u003cstrong\u003eATI Model H10-14 Low Range Ozone (O3) Smart Sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/H10-14_O3_Specifications.pdf?v=1634650813\"\u003eH10-14LR Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eModel H10-14 Ozone sensor is an electrochemical device used for the detection of O3 gas leaks in ambient air. It is designed to be used in conjunction with ATI’s Model F12 toxic gas transmitters. H10-14 sensors contain internal electronics and\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ememory that control sensor bias and store calibration data, calibration history, and limited data log. O3 sensors operate by generating a small electrical current proportional to the partial pressure of ozone gas in the surrounding air. The current is the result of the reduction of ozone on the surface of a catalytic electrode, with a resulting signal that is linear with respect to ozone concentration. Ozone sensors are 3-electrode sensors and require oxygen to function.\u003c\/p\u003e\n\u003cp\u003eOperational and Performance Specifications\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003ePrimary Response\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e  Volume % O3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e0.01 – 5.00 PPM V\/V (0.02 – 9.8 mg\/m3 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eSensor Current\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e0.25 A\/PPM Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eSensor Current Variability\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e0.1 – 0.5 A\/PPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eLinearity\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e± 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003eT50 = 10 Seconds, T90 = 90 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e-20\u003cspan data-mce-fragment=\"1\"\u003e°\u003c\/span\u003e to +50\u003cspan data-mce-fragment=\"1\"\u003e°\u003c\/span\u003e C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eMemory\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003eInternal e2 memory for Calibration Data and Calibration History\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.2px;\"\u003e\n\u003ctd style=\"height: 18.2px;\"\u003ePressure Range\u003c\/td\u003e\n\u003ctd style=\"height: 18.2px;\"\u003e- 5 to + 50 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003ePressure Variability\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003eOutput proportional to O3 partial pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e\n\u003cp\u003e0-99% RH Non-condensing (Intermittent)\u003cbr\u003e20-90% RH Non-condensing (Continuous)\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eZero Stability\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e± 0.02 PPM at constant temperature ± 0.03 PPM over ±10° C ambient temperature change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eSpan Drift\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e\u0026lt;2%\/Month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eTemperature Effect on Span\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003eSee Cutsheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eOperating Life\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e\u0026gt; 24 Months Typical in Clean Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eStorage Recommendation\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003eRecommended maximum of 1 year for best sensor performance. Store at less than 25\u003cspan data-mce-fragment=\"1\"\u003e°\u003c\/span\u003e C in a sealed container.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eSize\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e1” D x 1.25” H (25 mm x 32 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20px;\"\u003e\n\u003ctd style=\"height: 20px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 20px;\"\u003e17 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ATI","offers":[{"title":"Default Title","offer_id":41336944918713,"sku":"OZONE001008C161","price":422.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/ati03sensor.jpg?v=1634651150"},{"product_id":"ati-q46h-64-dissolved-ozone-monitor","title":"ATI Q46H-64 Dissolved Ozone Monitor","description":"\u003cp\u003e\u003cstrong\u003eATI F12-IS Toxic Gas Detector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/ATI_Q46-64_Dissolved_Ozone_Monitor.pdf?v=1634744527\"\u003eATI Q46-64 Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/ATI_Q46H-64_TypicalSpecs.pdf?v=1634744527\"\u003eATI Q46-64 Typical Specification\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eATI’s Model Q46H\/64 Dissolved Ozone Monitor provides an economical and reliable measurement system for water quality monitoring and controlling ozone treatment systems. With a variety of outputs including 4-20 mA analog, PID control, three adjustable relays, and digital communications, the Q46H\/64 is adaptable to any ozone application.\u003cbr\u003e \u003cbr\u003eINTERFERENCE-FREE DISSOLVED OZONE MEASUREMENT\u003cbr\u003eQ46H\/64 monitors use a polarographic membraned sensor to accurately measure Ozone in water. The sensor operates much like a battery, generating current that is linearly proportional to the concentration of chlorine dioxide in solution. An Ozone permeable membrane isolates the sensor from the measured sample and insures that the measurement is interference free.\u003cbr\u003e \u003cbr\u003eTwo versions of the sensor are available, a sensor intended for installation in a flowcell and a sensor intended for submersion applications. Requiring minimal maintenance, sensors are easy to use and easy to maintain. An integral RTD provides temperature compensation and allows temperature to be displayed and transmitted from the monitor.\u003cbr\u003e \u003cbr\u003eSENSOR STABILIZATION\u003cbr\u003eOzone sensors require 2 to 4 hours of stabilization time when first installed or after membrane change. ATI offers a battery powered “polarizer” that can be used to stabilize a spare sensor so it is ready to run within a few minutes of installation. Polarizers simply plug into the sensor connector and require no adjustments.\u003cbr\u003e \u003cbr\u003eSENSOR \u0026amp; FLOWCELL OPTIONS\u003cbr\u003eDissolved Ozone sensors require a steady flow of sample across the membrane at the tip of the sensing assembly. ATI offers a number of options for flowcells, including the standard constant-head overflow system, a sealed flowcell for pressures up to 50 PSI, and a low-volume flowcell where low sample flow is important. A 1-½” flow tee is also available for in-line applications with reliable constant flow and pressure conditions. For simplicity of installation, complete flow control assemblies are available.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"ATI","offers":[{"title":"Default Title","offer_id":41347578822841,"sku":"OZONEQ46H64111111","price":3499.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/products\/ATI_Q46-64.jpg?v=1634744665"},{"product_id":"ati-a10-19-oxygen-sensor","title":"ATI A10-19 Oxygen Sensor","description":"\u003cdiv\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003cem\u003eATI A10-19 Oxygen Sensor\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eFor use in ATI A14\/A11 and B12 gas monitors. 0-25% range. Plugs into the B12 gas monitor and requires local calibration (zero \u0026amp; span) per manual.\u003c\/p\u003e","brand":"ATI","offers":[{"title":"Default Title","offer_id":43365493342393,"sku":"MISCO2ATI000089","price":253.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/ATIA10-19OxygenSensor.png?v=1708539835"},{"product_id":"ati-oxygen-sensor-calibration-adaptor-00-0118","title":"ATI Oxygen Sensor Calibration Adaptor 00-0118","description":"\u003cdiv\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003e\u003cem\u003eATI Oxygen Sensor Calibration Adaptor for A10 sensors on ATI B12 gas monitors\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"ATI","offers":[{"title":"Default Title","offer_id":43365505564857,"sku":"OZONEGTB12000118CALI","price":35.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/0771\/files\/00-0118.png?v=1692819453"}],"url":"https:\/\/shop.prmfiltration.com\/collections\/ati.oembed","provider":"PRM Filtration","version":"1.0","type":"link"}